Power Transmission & Distribution Trainer (Model: XPO-SPS/TLD)

Introducing the Power Transmission & Distribution Trainer (Model: XPO-SPS/TLD), a comprehensive setup designed for the study of transmission lines, distribution transformers, and protection systems. Ideal for studying short and long-line Pi models, Ferranti effects, load regulation/efficiency calculations, as well as symmetric and asymmetric fault studies. Covers the protection of transmission lines using a multi-function numeric distance protection relay and the protection of distribution transformers using a multi-function numeric transformer protection relay. Protection relays are connected to RTU/SCADA over RS485, enabling the display of fault records on the SCADA screen for enhanced monitoring and analysis. Equipped with an emergency stop mushroom switch featuring a security key lock on the profile rack, ensuring operational safety.

SALIENT FEATURES

  • This setup is used for transmission line study for short as well as long line Pi model, Ferranti effects, load regulation / efficiency calculations, symmetric/asymmetric fault study. This setup also covers protection of transmission line using multi function numeric distance protection relay and of distribution transformer using multi function numeric transformer protection relay.
  • The protection relays are connected to RTU/SCADA over RS485 to display all fault records on SCADA screen.
  • Emergency stop mushroom switch is provided with security key lock on the profile rack.
  • Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords and shrouded socket arrangements for high voltage circuits.
  • Each panel has ABS moulded plastic sturdy enclosure, and colourful screwless overlays showing circuits diagrams & its connection tag numbers for easy understanding and connection.
  • Useful for Under Graduate Practical’s, Post Graduate Projects and Research Purpose.
  • Set of Instructor Guide & Student Workbook.

Technical Specifications

XPO- SPS/TLD trainer can work in standalone mode as well as in conjunction with HMI, RTU SCADA software and consists of following panels:

Input 3 phase DOL Starter panel (EMT1) X 1 No

  • 4 pole MCB of 415 V/4A.
  • DOL16AContactor with 24DCV / 11VACOIL
  • Bimetallic thermal O/L relay with range 2.5A- 6A
  • RYB inputs indicators.
  • 9 pin D (M) connector for RTU/SCADA interface.
  • Manual start / stop with local trip contact
  • Power ON LED indicator
  • Green SBS5 socket is provided for extend earth.

FWD-OFF-REV, Switch Panel (EMT 4A) X 1 No.

  • FWD/REV, 3 pole 3 way switch with centre OFF, 6A/440V.

VAR Compensation panel (dual panel) (EMT43) X 1 No.

  • Consisting of VAR compensating capacitors of 2, 4, 6, 8, 10 & 15μF each of 3 nose with 3 pole 7 way switch for selection.

CT panel (EMT48) ) X 2 No.

  • Consist of 5/5 Amp. CT6 Nos.
  • Primary side of CTs are brought on 3 x 2 x 2 SBS-5 sockets.
  • Secondary side of CTs are Star connected in group of 3 & brought out on 4 x 2 SBS-5 sockets