Get In Touch

Fire Alarm Trainer (Model : XPO-FAT)

This 2-Zone conventional fire alarm control panel stands out with its features geared towards effective training and demonstration. Equipped with built-in standby batteries, the panel showcases the functioning of the Fire Alarm and Detection System (FAT) even during mains supply failures. The system allows hands-on training by using 4mm patch cords to construct FAT circuits with various fire detectors. Housed in a durable ABS moulded plastic enclosure, each panel features colourful screwless overlays displaying circuit diagrams and connection tag numbers for easy understanding and connections. The inclusion of real-time simulations and activation of the fire alarm control system enhances the training experience.

SALIENT FEATURES:

  • 2-Zones conventional fire alarm control panel.
  • Has built in standby batteries to demonstrate working of FAT system in case of mains supply failure.
  • Facilitate hands on training through use of 4mm patch cords by constructing FAT circuits using various fire detectors.
  • Each panel has ABS moulded plastic sturdy enclosure, and colourful screw less overlays showing circuit diagram & its connection tag nos. for easy understanding & connections.
  • Provides real time simulations and activation of the fire alarm control system.
  • Set of Instructor Guide & Student Workbook

Technical Specifications

Aluminium profile modular flat demo panel rack system (table top) carrying various components housed in plastic enclosures (panels) to minimize shock possibility, in top three rows. The bottom row holds control panel with batteries.

  • 1 Phase AC Input Supply Panel (EMT16A)
    1 ph. dual MCBs of 2Afor short circuit protection
  • Smoke detector panel (FAT1) x 4 Nos.
    Photoelectric smoke sensor
    Operating voltage – 12VDC
    Standby current – 20uA
    Alarm current – 35mA@12VDC
    Alarm output – Remote LED
    Temperature range – 0% ~ 95%RH
  • Heat detector panel (FAT2) x 4 Nos.
    Operating voltage : 12VDC
    Static current : <55uA
    Alarm current : <25mA@12VDC
    Alarm output : Remote LED ON,
    Temperature trip point :135°F (57°C)
    Operating temperature : -10°C ~ +50°C, < 95% RH
    Detecting range:50 square meter with the installation
    height of 6m: 12m
  • Manual Call Point (MCP) panel (FAT4) x 2
    Nos.
    Operating voltage : 12VDC
    Resettable type : MCP
    Active/ de active LED indication
    Push to activate & deactivate by plastic key